China moving sidewalk walkway manufacturer used by centro comercial
Product Description
Function |
Description of functions |
1. Lack of phase, error phase protection | If lack of phase or error phase has been checked out, the escalator (moving walkway ) will automatically shop the operation. |
2. Motor over-load protection | When the current exceeds 15% of the current rating, the escalator will be automatically stop the operation. |
3. Electrical appliance loop protection | It offers the automatic circuit disconnecting device to protect the circuit and mains components of the escalator (moving walkway). |
4. Handrail inlet protection | When some foreign substance has been clipped in the handrail inlet, the escalator (moving walkway) will automatically stop the operation. |
5. Comb plate safety device | When some foreign substance has been clipped in or between the combs, the escalator (moving walkway) will automatically stop the operation. |
6. Step sagging protection device | When there is abnormal step bending, the escalator (moving walkway) will stop the operation before the step entering into the comb plate. |
7. Broken drive-chain safety device | When the drive-chain has been over-stretched or it is broken, the escalator (moving walkway) will automatically stop the operation. |
8. Broken step chain protection | When the step (plate) chain has been over-stretched or it is broken, the escalator (moving walkway) will automatically stop the operation. |
9. Over-speed protection | When there is over-speed to the escalator (moving walkway), it will automatically stop the operation. |
10. Direction recersal protection | When it comes the unintentional reversal of the direction of travel, the escalator (moving walkway) will automatically stop the operation. |
11. Security line | The yellow synthetic resin security line is located in the front position and two sides of the escalator tread so that the passengers will not tread in-between the edge of the adjacent step and the lift group lengthened skirt panel. The security line on both sides of the step is higher than the tread surface. (The moving walkway offers the selective yellow spray-painted security line.) |
12. Emergency stop button | When the button has been pressed down, the escalator (moving walkway) will stop the operation. |
13. Skirt panel protection | When some foreign substance has been clipped in between the skirt panel and the step, the escalator (moving walkway) will automatically stop the opertion. |
14. Brake protection | When the electric force falls short of supply or it acts any of the safety device, the brake function goes into effect by the safety device through the spring resilience action. In this way, the escalator (moving walkway) stops the operation. |
15. Safety inspection switch | It is a safety device to prevent from the escalator starting during the inspection and maintenrance. |
16. Step illumination | Illumination exists in the upper and lower ends of the escalator, in the lower part of the step in order to remind the passengers of the security matters. |
17. Alarm bell starting device | The alarm bell rings when it starts the escalator in order to remind the passengers of the security matters. |
18. Control device for handrail breakage | When the handrail is broken, the escalator will automatically stop the operation. |
19. Skirt panel brush | The brush that has been installed between the skirt panel and step will prevent the passengers from touching the skirt panel. (It is not merely restricted to the escalator.) |
20. VVVF variable frequency energy-saving system | When choose the frequency converter, it can effectively reduce the energy consumption. |
21. Comb illumination | The illumination has been installed in the skirt panel near the comb plate. It offers the lighting for the step and the comb plate. It is more convenient for the passengers to up and down the escalator. |
22. Handrail illumination | The handrail illumination has been installed in the handrail frame. The gentle light adds charm to the running escalator. |
23. Automatic start / stop | The infrared ray sensor which is near the floor plate can detect the passenger that enter into the floor plate. Then it will automatically start the operation. After all the passengers leave, it will automatically stop the operation again in order to save the energy loss. Scanning sensor and traditional guide rod are available for your choice. |
30° ESCALATORConstruction sketch30° Escalator elevator parameter list
Model | Travelling height (mm) | Net weight KN | Supporting | Motor power | Transport size | ||
R1 KN | R2 KN | H | L | ||||
GRF(600)-30° (4500 persons/h) speed 0.5m/s | 3000 | 57 | 46 | 41 | 8 | 2750 | 10900 |
3500 | 60 | 49 | 44 | 2780 | 11890 | ||
4000 | 64 | 52 | 47 | 2810 | 12880 | ||
4500 | 68 | 56 | 50 | 2830 | 13870 | ||
5000 | 71 | 59 | 53 | 2840 | 14860 | ||
5500 | 75 | 62 | 56 | 2860 | 15860 | ||
6000 | 65 | 65 | 59 | 2870 | 16860 | ||
GRF(800)-30° (6750 persons/h) speed 0.5m/s | 3000 | 59 | 52 | 47 | 8 | 2750 | 10900 |
3500 | 63 | 56 | 50 | 2780 | 11890 | ||
4000 | 67 | 60 | 54 | 2810 | 12880 | ||
4500 | 71 | 64 | 57 | 2830 | 13870 | ||
5000 | 74 | 68 | 60 | 11 | 2840 | 14860 | |
5500 | 82 | 74 | 66 | 2860 | 15860 | ||
6000 | 86 | 78 | 69 | 2870 | 16860 | ||
GRF(1000)-30° (9000 persons/h) speed 0.5m/s | 3000 | 63 | 59 | 53 | 8 | 2750 | 10900 |
3500 | 67 | 64 | 57 | 2780 | 11890 | ||
4000 | 71 | 68 | 61 | 2810 | 12880 | ||
4500 | 75 | 73 | 65 | 2830 | 13870 | ||
5000 | 83 | 79 | 71 | 11 | 2840 | 14860 | |
5500 | 87 | 84 | 75 | 2860 | 15860 | ||
6000 | 92 | 88 | 79 | 2870 | 16860 |
Step width (mm) | A | B | C | D | E | F |
1000 | 1000 | 1158 | 1238 | 1600 | 1660 | 2310 |
800 | 800 | 958 | 1038 | 1400 | 1460 | 2110 |
600 | 600 | 758 | 838 | 1200 | 1260 | 1910 |
Model | Travelling height (mm) | Net weight KN | Supporting | Motor power | Transport size | ||
R1 KN | R2 KN | H | L | ||||
GRF(600)-35° (4500 persons/h) speed 0.5m/s | 3000 | 54 | 43 | 39 | 8 | 2850 | 10180 |
3500 | 57 | 46 | 41 | 2890 | 11030 | ||
4000 | 60 | 59 | 44 | 2920 | 11890 | ||
4500 | 64 | 52 | 46 | 2940 | 12750 | ||
5000 | 67 | 54 | 49 | 2970 | 13610 | ||
5500 | 70 | 57 | 51 | 2980 | 14470 | ||
6000 | 63 | 60 | 54 | 3000 | 15330 | ||
GRF(800)-35° (6750 persons/h) speed 0.5m/s | 3000 | 56 | 49 | 44 | 8 | 2850 | 10180 |
3500 | 60 | 52 | 47 | 2890 | 11030 | ||
4000 | 63 | 56 | 50 | 2920 | 11890 | ||
4500 | 66 | 59 | 53 | 2940 | 12750 | ||
5000 | 70 | 62 | 56 | 11 | 2970 | 13610 | |
5500 | 73 | 65 | 59 | 2980 | 14470 | ||
6000 | 76 | 69 | 61 | 3000 | 15330 | ||
GRF(1000)-35° (9000 persons/h) speed 0.5m/s | 3000 | 60 | 56 | 30 | 8 | 2850 | 10180 |
3500 | 64 | 60 | 53 | 2890 | 11030 | ||
4000 | 67 | 64 | 57 | 2920 | 11890 | ||
4500 | 71 | 67 | 60 | 2940 | 12750 | ||
5000 | 74 | 71 | 64 | 11 | 2970 | 13610 | |
5500 | 82 | 77 | 69 | 2980 | 14470 | ||
6000 | 85 | 81 | 72 | 3000 | 15330 |
Step width (mm) | A | B | C | D | E | F |
1000 | 1000 | 1158 | 1238 | 1600 | 1660 | 2310 |
800 | 800 | 958 | 1038 | 1400 | 1460 | 2110 |
600 | 600 | 758 | 838 | 1200 | 1260 | 1910 |
(KN) The construction supporting force includes the vibration load. | ||||||||||
No intermediate supporting | One intermediate supporting | Two intermediate supporting | ||||||||
Ro=0.0045XL+13 | Ro=0.0045XLa+13 | Ro=0.0045XLa+13 | ||||||||
Ru=0.0045XLb+7 | Ru=0.0045XLb+7 | |||||||||
Ru=0.0045XL+7 | S1=0.00585X(La+Lb) | S1=0.00585X(La+Lc) | ||||||||
S2=0.0058X(Lb+Lc) | ||||||||||
Traveling height | Intermediate supporting6754 | La (mm) | Lb (mm) | Lc (mm) | Intermediate supporting height | |||||
From | To | S1 | S2 | |||||||
1601 | 2663 | - | - | - | - | - | Hm1 | 0.2126×Lb-1051 | ||
2664 | 4151 | 1 | - | L-7000 | 7000 | - | ||||
4152 | 3500 | 1 | - | 15000 | L-15000 | - | Hm2 | 0.2126×(Lb+Lc)-1066 | ||
5852 | 4000 | 1 | 1 | 15000 | 7000 | L-22000 |
Tread width A (mm) | 1000 | 800 |
Central distance of the handrail B (mm) | 1238 | 1038 |
Outline width C (mm) | 1600 | 1400 |
Supporting beam width in the well D (mm) | ≥1660 | ≥1460 |
Preset width in the well E (mm) | 2310 | 2110 |
Model | Traveling height (mm) | Rated speed (m/s) | Rated load capacity (person/h) | lnclination | Motor power (kW) | A (mm) | B (mm) | C (mm) | D (mm) |
GRR (800/0°) | 80000 | 0.5 | 6750 | 0 | 5.5 | 800 | 1038 | 1400 | ≥1460 |
80000 | 8 | ||||||||
130000 | 11 | ||||||||
GRR (1000/0°) | 70000 | 0.5 | 9000 | 0 | 5.5 | 1000 | 1238 | 1600 | ≥1660 |
70000 | 8 | ||||||||
110000 | 11 |
Our ServicesHelp Customers Source in China to reduce their costTo provide customers with whole purchasing plan of elevator parts;To find out the best conjunction point between quality and price in order to reduce costs for them. How to develop the suppliers for customersTo get customers' need through communicating.To find out three to four manufactures of the corresponding parts according to the request of the customers.Ask price
and get samples from the manufactures.To visit the factory (acknowledge the production ability and quality control process).Basing on the price, sample and visiting, recommend manufacturers to our customers. How to help customers order from the qualified suppliers Follow the process of the order. Send QC to inspect on site before shipping to acknowledge the product quality.Transfer the response from the customers to the suppliers on time, and follow up the improvement. Special package servicesGather Sourced Parts for Dispatch (Less than one container Shpt. Service)Help customers shipping products directly to the working site oversea:Quick Response Company Information FAQQualification system certification,certificate of honorWhy UsXIWEIYOUR BEST CHOICE! Contact us if you need more details on Moving Walkway Manufacturer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Moving Sidewalk、Centro Comercial. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Moving Sidewalk